beautypg.com

Avago Technologies Cache Protection for RAID Controller Cards User Manual

Page 102

background image

Avago Technologies

- 102 -

Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015

Chapter 2: Installing the Cache Backup Products

Attaching the CVFM03 Module to a MegaRAID SAS 9265CV-8i RAID Controller and

Connecting to a Remote CVPM02 Module

2.10.6

Reinstalling the RAID Controller on the Motherboard

Follow these steps to reinstall the RAID controller on the motherboard.

1.

Make sure the power to the chassis is still turned off, the power cords are unplugged, and the chassis is grounded
and has no AC power.

2.

Install the RAID controller in a PCI Express slot on the motherboard, as shown in the following figure.

NOTE

Some PCI Express slots support only PCI Express graphics cards. If a
RAID controller is installed in one of these slots, the controller does not
function. Refer to your computer documentation for information
about the PCI Express slot.

3.

Press down gently, but firmly, to seat the card correctly in the slot.

4.

Secure the controller to the computer chassis with the bracket screw.

Figure 70 Reinstalling the RAID Controller on the Motherboard

5.

Replace the computer cover and reattach the power cords.

6.

Turn on the power to the computer.

CacheVault

Power Module 02

(CVPM02)

Edge of

Motherboard

PCIe Slot

3_00916-01

Bracket
Screw

Press

Here

Press

Here

Remote Mount

Board

CacheVault
Flash Module 03
(CVFM03)