Section 2.3.6.2, installing – Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 37

Avago Technologies
- 37 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 2: Installing the Cache Backup Products
Installing the LSIiBBU06 Unit
2.3.6.2
Installing the Board-to-Board Cable Adapter Card on the RAID Controller
Follow these steps to install the board-to-board adapter card on the controller.
1.
With the controller on a flat, clean, static-free surface, ground yourself, and remove the adapter card, standoff, and
screws from the package.
2.
Place the standoff on the controller so that the bottom side is positioned over the screw hole next to the J1
connector on the controller.
3.
Use one of the screws to secure the standoff to the controller, as shown in the following figure.
NOTE
Center the screwdriver carefully to avoid stripping the screw head.
Do not overtighten the screws.
4.
Hold the adapter card so that the J2 board-to-board connector lines up with the J10 board-to-board connector
on the RAID controller.
5.
Carefully press the J2 connector on the adapter card into the J10 connector on the controller so that the two
connectors are joined firmly.
6.
The connectors fit only when they are in the correct alignment.
7.
Use the other screw to secure the adapter card to the controller, and continue with the next procedure.
Figure 20 Connecting the Board-to-Board Adapter Card to the MegaRAID SAS 8708EM2 RAID Controller
3_00719-00
J10