Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 90

Avago Technologies
- 90 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 2: Installing the Cache Backup Products
Connecting a CVFM02 Module on a RAID Controller to a CVPM02 Module Mounted on a
Remote Mount Board
2.9
Connecting a CVFM02 Module on a RAID Controller to a CVPM02 Module
Mounted on a Remote Mount Board
This section describes how to install a CVPM02 module on a remote mount board, and then connect it by cable to
a CVFM02 module that is installed on a RAID controller. You can do perform these actions on the following
RAID controllers:
MegaRAID
SAS 9266-4i
MegaRAID
SAS 9266-8i
MegaRAID SAS 9271-4i
MegaRAID SAS 9271-8i
MegaRAID SAS 9271-8iCC
The example in this section uses a MegaRAID SAS 9266-8i RAID controller. You can perform these procedures on the
other RAID controllers in a similar way.
2.9.1
Removing the RAID Controller from the Host Computer
If the RAID controller is already installed in the host computer, follow these steps to remove it before you install the
CVPM02 module.
1.
Shut down the computer, turn off the power, and unplug the power cords.
2.
Remove the cover from the computer according to the instructions in the system user’s manual so that you can
access the RAID controller.
3.
Ground yourself before touching the RAID controller.
4.
Unplug all cables from the RAID controller, remove the screw that attaches the bracket to the computer case, and
carefully remove the RAID controller from the slot.
5.
Place the RAID controller on a flat, clean, static-free surface, and continue with the next section.