beautypg.com

Electrical installation 2 - 29 – Yaskawa F7 Drive User Manual User Manual

Page 56

background image

Electrical Installation 2 - 29

4037

FS5972-100-35

or

FS5972-130-35

B

100A

or

130A

9.92 (4.5)

or

10.36 (4.7)

3.54 x 12.83 x 5.9

(90 x 326 x 150)

or

3.54 x 14.375 x 7

(90 x 366 x 180)

4045

4055

FS5972-130-35

B

130A

10.36

(4.7)

3.54 x 14.375 x 7

(90 x 366 x 180)

4075

FS5972-170-40

B

170A

13.23

(6)

4.75 x 17.75 x 6.6675

(120 x 451 x 170)

4090

FS5972-250-37

or

FS3359-250-28

A

250A

24.25 (11)

or

15.43 (7)

5.125 x 24 x 9.475

(130 x 610 x 240)

or

9.05 x 11.80 x 4.92

(230 x 300 x 125)

4110

4132

FS5972-400-99

or

FS3359-400-99

A

400A

23.15 (10.5)

or

40.78 (18.5)

10.24 x 15.20 x 4.53

(260 x 386 x 115)

or

11.81 x 24.01 x 6.30

(300 x 610 x 160)

4160

4185

FS5972-410-99

A

410A

23.15 (10.5)

10.24 x 15.20 x 4.53

(260 x 386 x 115)

4220

FS5972-600-99

A

600A

24.25

(11)

10.24 x 15.20 x 5.31

(260 x 386 x 135)

4300

FS5972-800-99

A

800A

68.34

(31)

11.81 x 28.19 x 6.30

(300 x 716 x 160)

* Maximum Voltage:

480Vac 3-phase

Ambient Temperature:

45 Degrees Celsius (maximum)

Maximum motor cable length:

50m Class B, 50m Class A

Permissible emission of power drive systems for commercial and light environment (EN61800-3, A11) (General availability, 1st environment)

Table 2.16 Recommended EMC Filters (Continued)

Drive Model

CIMR-F7U

EMC Filter

Model Number

EN

55011

Class*

Current

Rating

Weight

lb.

(kg)

Dimensions

inches

(mm)