beautypg.com

Drive output specifications, 240vac – Yaskawa F7 Drive User Manual User Manual

Page 5

background image

iv

Drive Output Specifications

The standard Drive specifications are listed in the following tables.

208-240Vac

Table i.2 208-240Vac Drive Specifications

208-240Vac

208-230Vac

Model Number CIMR-F7U

20P4

20P7

21P5

22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030

2037

2045

2055

2075

2090 2110

*5

Rated output

capacity

(kVA)

1.2

1.6

2.7

3.7

5.7

8.8

12.0

17.0

22.0

27.0 32.0 44.0

55.0

69.0

82.0

110.0

130.0 140.0

Horsepower

*2

0.5/0.75

1

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

125

150

Rated output

current

(A)

3.2

4.2

7.0

9.6

15.2

23.0

31.0

45.0

58.0

71

85.0 115.0 145.0 180.0

215

283.0

346.0 360.0

Overload capacity

*3

(% of rated output
current for 60 sec.)

150

138

*3

Current limit (% of
rated output current)

150

138

*3

Carrier frequency

*4

2kHz

Maximum output
frequency

300.0Hz

Rated output

capacity

(kVA)

1.4

1.8

3.0

4.1

6.4

8.8

12.0

18.0

23.0

29.0 34.0 44.0

62.0

73.0

82.0

120.0

140.0 160.0

Horsepower

*2

0.5/0.75

1

2

3

5

7.5

10

15

20

25

30

40

50/60

75

75

100/125

150

150

Rated output

current

(A)

3.6

4.6

7.8

10.8

16.8

23.0

31.0

46.2

59.4

74.8 88.0 115.0 162.0 192.0

215

312.0

360.0 415.0

Overload capacity

*3

(% of rated output
current for 60 sec.)

107

107

108

107

107

120

120

117

117

114

116

120

107

113

120

109

115

120

Current limit (% of
rated output current)

120

Carrier frequency

(kHz)

*5

10

10

10

8

10

15

15

8

10

10

10

10

5

5

8

2

2

2

Maximum output
frequency

400.0Hz

Maximum output voltage

3-phase; 200, 208, 220, 230, or 240Vac

(Proportional to input voltage)

*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and

maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).

*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor

and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current.

*3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of

rated output current for 45 seconds and a current limit rating of 150%.

*4 When setting the carrier frequency above the factory default, the Drive must be derated.
*5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.

Out

put

r

at

ings

Heavy Du

ty

*1

Norma

l Duty

*1