Basic Programming 5 - 14

Table 5.3 Preset V/F Patterns

Specifications

E1-03

V/F Pattern

Specifications

E1-03

V/F Pattern

General-purpo

se

50Hz

0

Hig

h

Starting Torque

50Hz

High

Starting

Torque 1

8

High

Starting

Torque 2

9

60Hz

1

or

F

60Hz

High

Starting

Torque 1

A

60Hz

(with 50Hz Base)

2

High

Starting

Torque 2

B

72Hz

(with 60 Hz Base)

3

High Speed

Operation

90Hz

(with 60Hz Base)

C

Variable Torq

ue

50Hz

Variable

Torque 1

4

120Hz

(with 60Hz Base)

D

Variable

Torque 2

5

60Hz

Variable

Torque 1

6

180Hz

(with 60Hz Base)

E

Variable

Torque 2

7

IMPORTANT

When a factory initialization is performed and the setting of E1-03 = F or FF, E1-03 is unaffected, but the
settings of E1-04 through E1-13 are returned to their factory default settings.

(Hz)

(V)

230

17
10

0 1.3 2.5

50

0

230

(V)

28

22

15

13

(Hz)

0 1.3 2.5

50

9

8

(Hz)

0 1.5 3.0

50 60

17
10

2

1
F

(V)

230

230

(V)

28

22

17

13

(Hz)

0 1.5 3.0

B

A

60

(Hz)

0 1.5 3.0

60 72

17
10

3

(V)

230

(Hz)

0 1.5 3.0

60 90

17
10

C

(V)

230

230

(V)

57
40

10

9

(Hz)

0 1.3

25

50

5

4

(Hz)

0 1.5 3.0

60 120

17
10

D

(V)

230

230

(V)

57
40

10

9

(Hz)

0 1.5

30

60

7

6

(Hz)

0 1.5 3.0

60 180

17
10

E

(V)

230