beautypg.com

Yaskawa F7 Drive User Manual User Manual

Page 116

background image

Basic Programming 5 - 15

E1-04 Maximum Output Frequency

Setting Range:

40.0 to 400.0Hz

Factory Default: 60.0Hz

E1-05 Maximum Output Voltage

Setting Range:

0.0 to 255.0V (240V Models)
0.0 to 510.0V (480V Models)

Factory Defaults: 230.0V (240V Models)

460.0V (480V Models)

E1-06 Base Frequency

Setting Range:

0.0 to 400.0Hz

Factory Default: 60.0Hz

E1-09 Minimum Output Frequency

Setting Range:

0.0 to 400.0Hz (Normal Duty)
0.0 to 300.0Hz (Heavy Duty)

Factory Default: 1.5Hz

E1-13 Base Voltage

Setting Range:

0.0 to 255.0V (240V Models)
0.0 to 510.0V (480V Models)

Factory Defaults: 0.0V (240V Models)

0.0V (480V Models)

To set up a custom V/F pattern, program the points shown in the diagram below using parameters E1-04 through E1-13. Be
sure that the following condition is true:

E1-09

≤ Ε1−07 < Ε1−06 ≤ Ε1−11 ≤ Ε1−04

Fig 5.9 V/F Pattern Parameters

Parameters E1-07, E1-08, E1-10, E1-11, and E1-12 are accessible through the Programming Menu.

Frequency

Voltage

E1-09 E1-07

E1-06

E1-04

E1-11

Max Voltage E1-05

Mid Voltage B E1-12

Mid Voltage A E1-08

Base Voltage E1-13

Min Voltage E1-10

Min

Freq

Max

Freq

Base

Freq

Mid

Freq

A

Mid

Freq B

Mid

Freq A