Parameters A - 20

DI-08, 16 Setup

F3-01

DI-08 / DI-16H2 Input
Selection
DI Input

Sets the function of the DI-08 or the DI-16H2 digital input option
board.

0: BCD 1% unit
1: BCD 0.1% unit
2: BCD 0.01% unit
3: BCD 1Hz unit
4: BCD 0.1Hz unit
5: BCD 0.01Hz unit
6: BCD (5-digit) 0.01Hz unit (only effective when DI-16H2 is

used.)

7: Binary input

When o1-03 is set to 2 or higher, the input will be BCD, and the
units will change to the o1-03 setting.

0 to 7

0

A

A

A

A

AO-08, 12 Setup

F4-01

AO-08/AO-12 Channel 1
Monitor Selection
AO Ch1 Sel

Sets the number of the monitor item to be output. (U1-

)

The following settings cannot be set:
4, 10 to 14, 25, 28, 29, 30, 34, 35, 39, 40, 41.

1 to 45

2

A

A

A

A

F4-02

AO-08/AO-12 Channel 1
Gain
AO Ch1 Gain

Sets the channel 1 gain.
Ex: Set F4-02 = 50% to output 100% at 5.0V output.

0.0 to

1000.0

100.0%

A

A

A

A

F4-03

AO-08/AO-12 Channel 2
Monitor Selection
AO Ch2 Sel

Sets the number of the monitor item to be output. (U1-

)

The following settings cannot be set:

4, 10 to 14, 25, 28, 29, 30, 34, 39, 40, 41.

1 to 45

3

A

A

A

A

F4-04

AO-08/AO-12 Channel 2
Gain
AO Ch2 Gain

Sets the channel 2 gain.
Ex: Set F4-04 = 50% to output 100% at 5.0V output.

0.0 to

1000.0

50.0%

A

A

A

A

F4-05

AO-08/AO-12 Channel 1 Out-
put Bias
AO Ch1 Bias

Sets the channel 1 bias (100%/10V).
Ex: Set F4-05 = 50% to output 0% at 5.0V output.

-110.0 to

110.0

0.0%

A

A

A

A

F4-06

AO-08/AO-12 Channel 2 Out-
put Bias
AO Ch2 Bias

Sets the channel 2 bias (100%/10V).
Ex: Set F4-06 = 50% to output 0% at 5.0V output.

-110.0 to

110.0

0.0%

A

A

A

A

F4-07

AO-12 Channel 1 Signal
Level
AO Opt Level Ch1

Sets the range of the voltage output.
0: 0 to 10Vdc
1: -10 to +10Vdc

0 to 1

0

A

A

A

A

F4-08

AO-12 Channel 2 Signal
Level
AO Opt Level Ch2

Sets the range of the voltage output.
0: 0 to 10Vdc
1: -10 to +10Vdc

0 to 1

0

A

A

A

A

DO-02, 08 Setup

F5-01

DO-02/DO-08 Channel 1 Out-
put Selection
DO Ch1 Select

Sets the digital output function number for channel 1. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

0

A

A

A

A

F5-02

DO-02/DO-08 Channel 2 Out-
put Selection
DO Ch2 Select

Sets the digital output function number for channel 2. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

1

A

A

A

A

F5-03

DO-08 Channel 3 Output
Selection
DO Ch3 Select

Sets the digital output function number for channel 3. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

2

A

A

A

A

F5-04

DO-08 Channel 4 Output
Selection
DO Ch4 Select

Sets the digital output function number for channel 4. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

4

A

A

A

A

F5-05

DO-08 Channel 5 Output
Selection
DO Ch5 Select

Sets the digital output function number for channel 5. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

6

A

A

A

A

F5-06

DO-08 Channel 6 Output
Selection
DO Ch6 Select

Sets the digital output function number for channel 6. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

37

A

A

A

A

F5-07

DO-08 Channel 7 Output
Selection
DO Ch7 Select

Sets the digital output function number for channel 7. See the H2
parameter group for possible selections.
Effective when digital output card DO-02 or DO-08 is used.

0 to 38

F

A

A

A

A

Denotes that parameter can be changed when the Drive is running.

Table A.1 F7 Parameter List (Continued)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Control Method

V/F

V/F

w/PG

Open

Loop

Vector

Flux

Vector