Specifications C - 4

Common Specifications

Table C.2 480Vac Drive Specifications (Continued)

Model Number CIMR-F7U

4030

4037

4045

4055

4075

4090

4110

4132

4160

4185

4220

4300

Rated output capacity

(kVA)

46.0

57.0

69.0

85.0

110.0

140.0

160.0

200.0

230.0

280.0

315.0

450.0

Horsepower

*2

40

50

60

75

100

125/150

-

200

250

300

350

500

Rated output current (A)

60.0

75.0

91.0

112.0

150.0

180.0

216.0

260.0

304.0

370.0

414.0

590.0

Overload capacity

*3

(% of rated output current
for 60 sec)

150

150

*3

150

*3

Current limit

(% of rated

output current)

150

150

*3

150

*3

Carrier frequency

*5

2kHz

Maximum output
frequency

300.0Hz

Rated output capacity

(kVA)

51.0

59.0

73.0

95.0

120.0

140.0

180.0

200.0

230.0

315.0

390.0

510.0

Horsepower

*2

40/50

60

75

100

125

150

200

-

250

300/350

400/450

500+

Rated output current (A)

67.2

77.0

96.0

125.0

156.0

180.0

240.0

260.0

304.0

414.0

515.0

675.0

Overload capacity

*3

(% of rated output current
for 60 sec.)

107

117

114

108

115

120

108

120

120

107

118

120

Current limit

(% of rated

output current)

120

Carrier frequency (kHz)

*6

8

8

8

5

5

8

5

5

5

2

2

2

Maximum output
frequency

400.0Hz

Maximum output voltage

3-phase, 380, 400, 415, 440, 460 or 480Vac (Proportional to input voltage)

Rated voltage
Rated frequency

3-phase, 380, 400, 415, 440, 460, or 480Vac, 50/60Hz

Rated input current -

Heavy Duty

*1

(A)

66

83

100

120

165

198

238

286

334

407

457

649

Rated input current -

Normal Duty

*1

(A)

74

85

106

134

172

198

264

286

334

456

567

743

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency
fluctuation

±5%

Measures for
power supply
harmonics

DC Reactor

Built-in

12-Pulse
Rectification

Possible

*4

*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and

maximum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).

*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor

and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current.

*3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of

rated output current for 45 seconds and a current limit rating of 150%.

*4 When setting the carrier frequency above the factory default, the Drive must be derated.
*5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.
*6 Each value shown is the Maximum carrier frequency and default carrier frequency.
*7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a

reduction in continuous rated output current. Refer to C6-02 in Chapter 5 for further details.

O

u

tpu

t rat

ing

s

Heavy Du

ty

*

1

No

rm

al Du

ty

*

1

Power s

u

pp

ly c

h

ar

act

er

ist

ics

C

ont

ro

l c

h

arac

te

ri

st

ics

.