beautypg.com

Terminal connections, Electrical installation 2 - 19, Fig 2.9 terminal connections – Yaskawa F7 Drive User Manual User Manual

Page 46

background image

Electrical Installation 2 - 19

Terminal Connections

Connections to Drive terminals are shown in Fig 2.9.

External Fault

Fault Reset

Multi-Step Ref 1

Multi-Step Ref 2

Jog Reference

Baseblock

2-Wire

Control

Run command (run on momentary close)

Stop command (stop on momentary open)

Forward/reverse command (multi-function input)

Sequence input common

Fwd/Rev

S1

S2

S5

Stop
switch
(NC
contact)

Operation
switch
(NO
contact)

Run command (run on momentary close)

Stop command (stop on momentary open)

Forward/reverse command (multi-function input)

Sequence input common

Fwd/Rev

S1

S2

S5

Stop
switch
(NC
contact)

Operation
switch
(NO
contact)

3-Wire Control

SN

Digital Inputs 1-2

24Vdc, 8mA

Multi-function

Digital Inputs 3-8

24Vdc, 8mA

Fig 2.9 Terminal Connections