Table 5.1 HD Ratings for Various Carrier Frequencies

Model

CIMR-F7U

Continuous Amps (A)

*1

Carrier Frequency

2.0 kHz

5.0 kHz

8.0 kHz

10.0 kHz

12.5 kHz

15.0 kHz

20P4

3.2

3.1

2.9

2.8

2.7

2.6

20P7

4.2

4

3.8

3.7

3.5

3.4

21P5

7

6.7

6.4

6.2

5.9

5.6

22P2

9.6

9.2

8.8

8.4

8.1

7.7

23P7

15.2

14.6

13.9

13.4

12.8

12.2

25P5

23

22.1

21

20.2

19.3

18.4

27P5

31

29.8

28.3

27.3

26.0

24.8

2011

45

43.2

41

39.6

37.8

36.0

2015

58

55.7

52.9

51

48.7

46.4

2018

71

68.2

64.8

62.5

59.6

56.8

2022

85

81.6

77.5

74.8

71.4

68.0

2030

115

106.7

96.8

90.2

81.9

73.6

2037

145

127.6

106.7

92.8

No Increase in Carrier

Frequency Possible

2045

180

158.4

132.5

115.2

2055

215

189.2

158.2

137.6

2075

283

249

208.3

181.1

2090

346

304.5

254.7

221.4

2110

360

*2

40P4

1.8

1.7

1.6

1.6

1.5

1.4

40P7

2.1

2

1.9

1.8

1.8

1.7

41P5

3.7

3.6

3.4

3.3

3.1

3.0

42P2

5.3

5.1

4.8

4.7

4.5

4.2

43P7

7.6

7.3

6.9

6.7

6.4

6.1

44P0

8.7

8.4

7.9

7.7

7.3

7.0

45P5

12.5

12

11.4

11

10.5

10.0

47P5

17

16.3

15.5

15

14.3

13.6

4011

24

23

21.9

21.1

20.2

19.2

4015

31

29.8

28.3

27.3

26.0

24.8

4018

39

37.4

35.6

34.3

32.8

31.2

4022

45

43.2

41

39.6

37.8

36.0

4030

60

55.7

50.5

47

42.7

38.4

4037

75

69.6

63.2

58.8

53.4

48.0

4045

91

84.4

76.6

71.3

64.8

58.2

4055

112

103.9

94.3

87.8

79.7

71.7

4075

150

132

110.4

96

4090

180

158.4

132.5

115.2

4110

216

190.1

159

138.2

4132

260

228.8

191.4

166.4

4160

304

267.5

223.7

194.6

4185

370

296

No Increase in Carrier Frequency Possible

4220

414

*2

4300

590

*2

*1 All models have an overload rating of 150% of rated output current for 60 seconds except model 2110, which has an overload rating of

138% of rated output current for 60 seconds, and models 4220 and 4300, which have an overload rating of 150% of rated output current
for 45 seconds.

*2 Heavy Duty Ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.