Standard drive specifications, 240vac, Specifications c - 2 – Yaskawa F7 Drive User Manual User Manual

Page 215

background image

Specifications C - 2

Standard Drive Specifications

The standard Drive specifications are listed in the following tables.

208-240Vac

Table C.1 208-240Vac Drive Specifications

208-240Vac Drives

208-230Vac Drives

Model Number CIMR-

F7U

20P4

20P7

21P5

22P2

23P7

25P5

27P5

2011

2015 2018 2022

2030

2037

2045

2055

2075

2090

2110

*5

Rated output

capacity

(kVA)

1.2

1.6

2.7

3.7

5.7

8.8

12.0

17.0

22.0

27.0

32.0

44.0

55.0

69.0

82.0

110.0

130.0 140.0

Horsepower

*2

0.5/0.75

1

2

3

5

7.5

10

15

20

25

30

40

50

60

75

100

125

150

Rated output

current

(A)

3.2

4.2

7.0

9.6

15.2

23.0

31.0

45.0

58.0

71

85.0

115.0

145.0 180.0

215

283.0

346.0 360.0

Overload capacity

*3

(% of rated output
current for 60 sec)

150

138

*3

Current limit (% of
rated output current)

150

138

*3

Carrier frequency

*5,*7

2kHz

Maximum output
frequency

300.0Hz

Rated output

capacity

(kVA)

1.4

1.8

3.0

4.1

6.4

8.8

12.0

18.0

23.0

29.0

34.0

44.0

62.0

73.0

82.0

120.0

140.0 160.0

Horsepower

*2

0.5/0.75

1

2

3

5

7.5

10

15

20

25

30

40

50/60

75

-

100/125

150

-

Rated output

current

(A)

3.6

4.6

7.8

10.8

16.8

23.0

31.0

46.2

59.4

74.8

88.0

115.0

162.0 192.0

215

312.0

360.0 415.0

Overload capacity

*3

(% of rated output
current for 60 sec.)

107

107

108

107

107

120

120

117

117

114

116

120

107

113

120

109

115

120

Current limit (% of
rated output current)

120

Carrier frequency

(kHz)

*6

10

10

10

8

10

15

15

8

10

10

10

10

5

5

8

2

2

2

Maximum output
frequency

400.0Hz

Maximum output
voltage

3-phase; 200, 208, 220, 230, or 240Vac

(Proportional to input voltage)

Rated voltage
Rated frequency

3-phase, 200/208/220/230/240Vac, 50/60Hz

3-phase, 200/208/220/230Vac, 50/60Hz

Rated input current -

Heavy Duty

*1

(A)

3.8

4.9

8.4

11.5

18

24

37

52

68

84

94

120

160

198

237

317

381

396

Rated input current -

Normal Duty

*1

(A)

4.3

5.5

9.4

13

20

24

37

53

70

89

98

120

180

212

237

350

396

457

Allowable voltage
fluctuation

+ 10%, - 15%

Allowable frequency
fluctuation

±5%

Measures
for power
supply
harmonics

DC
Reactor

Optional

Built-in

12-Pulse
Rectification

Not possible

Possible

*4

*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and maxi-

mum output frequency. Parameter C6-01 must be set to value of “0” for Heavy Duty ratings and “2” for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).

*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive,

be sure that the Drive's rated output current is appropriate for the motor's rated current.

*3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of rated output

current for 45 seconds and a current limit rating of 150%.

*4 When setting the carrier frequency above the factory default, the Drive must be derated.
*5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.
*6 Each value shown is the Maximum carrier frequency and default carrier frequency.
*7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a reduction in

continuous rated output current. Refer to C6-02 in Chapter 5 for further details.

O

u

tpu

t rat

ing

s

Hea

v

y Duty

*

1

Norma

l Duty

*

1

Pow

er s

u

pp

ly c

h

ar

act

er

ist

ics

C

ont

ro

l c

h

arac

te

ri

st

ics