NavCom StarUtil-3000 Rev.G User Manual
Page 158
StarUtil 3000 User Guide
– Rev G
9-156
[OUTPUT] NMEAGGA,ONTIME,2,2
Outputs GGA messages ONTIME at 5Hz on Port 2. The keyword mnemonic, ONTIME,
outputs the message at a rate
the purchased rate.
The DTM message will automatically appear in the output field at the same rate as the GGA
message as follows:
[OUTPUT] NMEADTM,ONCHANGE,,2
The DTM message automatically displays at the same rate as the GGA. The keyword
mnemonic, ONCHANGE, outputs the message at the same rate set by the ONTIME
command.
Refer to the Sapphire Technical Reference Manual (TRM) for detailed information
on the output formats of NMEA messages and NavCom proprietary NMEA type
messages (see Related Documents in the fore-matter). In addition, refer to the
section, NMEA Messages Overview, in the TRM.
Click the word “Off” in the Rate column to display a drop-down arrow. Click the
arrow to display a drop-down list of Hz rates: 1 Hz, 5Hz,10Hz and Once. Select
from the list the Hz data rate you want (up to 10Hz) for that particular message.
Note that changes made here do not survive a power cycle.
Select the checkbox in the Paused column next to any message you want to
pause. When
“Paused,” the field does not update.
Click the heading of any column to sort the data.