WaveBook User’s Manual,

6-24-99

WaveView 5-7

File

New

Set all parameters to their default startup setting.

Save

Save the existing configuration for later recall.

Load

Load a saved configuration.

Load a WBK16 Cal

File (WBK16 Only)

Load a WBK16 sensor calibration table. This command loads saved WBK16 calibration

data.

Note: This selection will not be available unless WaveView detects the presence of a

WBK16.

Exit

Leave the WaveView program.

Edit

Make All Channels

Inactive

This command places an “Off” in the On field of all of the channels. If your channel scan

includes only a few channels, it may be easier to make all of the channels inactive, then
turn on only those few channels that you want.

Make All Channels

Active

This command places an “On” in the On field of all of the channels.

Go To Row

This command pops up a dialogue box that allows you to enter a channel number to be

modified. For hardware configurations that contain a large number of channels, this is a
faster method of moving around than using the scroll bars.

Fill Down

When multiple cells within a column are selected, this command takes the top-most

selected cell and copies its contents to the selected cells below.

Auto-Zero Enabled

Channels

This command will zero out a DC offset signal on all of the channels that are “On” and have

Auto-Zero set to “Yes.”

Enable Spreadsheet

Reading Column

This command will cause all channels that are “On” to display an actual reading of the input

signal in the channel reading column. This column is updated with new readings at a rate
of four times per second.

Disable Spreadsheet

Reading Column

This command will stop the reading column from being updated.

View

Acquisition

Configuration

Opens display window to allow selection of the number/speed of the scan and the triggering

method to start the acquisition.

Module Configuration

Opens the display window that shows the current inventory of expansion modules in the

system and allows the configuration of some expansion module parameters.

Scope

Opens the display window to allow real-time viewing of the acquired data.

Direct to Disk

Opens the display window to allow the writing of acquisition data to disk files.

PostView

Starts the PostView application.

System

Select Device

Opens the Select Device dialog box that shows you the current system devices to choose

from.

Simulated WaveBook

This command opens a WaveView session but does not attempt to communicate with

WaveBook hardware. Instead, the application simulates the interaction between the
software and hardware. If WaveView is presently attached to real WaveBook hardware,
this command will close that session.

WBK16 Sensor

Calibration
(WBK16 Only)

This command runs the sensor calibration program. Selecting this option will temporarily

disable WaveView and open a sensor calibration spreadsheet so that each channel on a
WBK16 can be calibrated to the specifications of the sensor in use. See Chapter 3:
WaveBook Expansion Options
on using a WBK16 for more information on the sensor
calibration program.

Note: This selection is available if WaveView detects a WBK16 module.

WBK16 Advanced

Features
(WBK16 Only)

This command brings up a dialog box to select new cutoff frequencies for the LPF on a

WBK16. The WBK16 has a Low Pass Filter with two selectable cutoff frequencies.
Although the frequencies are factory configured at 10 Hz and 1 kHz, changing the resistor
packs inside the WBK16 can modify them. After the cutoff frequencies are altered, the
values that WaveView displays can then be modified to match the LPF frequencies using
this command.

Note: This selection is available if WaveView detects a WBK16 module.

Options

This command opens the System Options window with its three tabs: Performance, Data

Files, and Memory Module, as shown and described on the following page.