beautypg.com

Connect the power, Connect the power -48 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 96

background image

InstallatIon

2-48

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

Connect the power

1. Insert the power cable through the strain relief at the rear of the fiber laser supply.
2. Open the rear door of the fiber laser supply enclosure and locate the main power terminal block.
3. Connect the power leads to the terminals as shown below.
4. verify that the line disconnect switch is in the OFF position and remains in the OFF position for

the remainder of the installation of the system.

5. Connect the power cord leads to the line disconnect switch following national and local electrical codes.

Wire colors

L1 = Red

L2 = White

L3 = Black

(PE) Earth ground = Green/yellow

1 L1

3 L2

5 L3

Line disconnect

switch

Power cable

Ground

Red

White

Black

DANGER

ELECtRICAL SHOCK CAN KILL

t

he line disconnect switch must be in the OFF position before making the power cable connections.

In the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other countries,

follow appropriate national

and

local safety procedures.