2 seconds

2 seconds

minimum

Pulse laser enable (CNC input)

2 seconds

Pulse laser enabled (CNC

output)

Pulse laser (input)

Hypertherm CNC interface

The Hypertherm CNC provides a built in interface for generating single laser pulses. This process uses the following

digital inputs and outputs:

Pulse Laser Enable (input) – Set active for 2 seconds to enable pulsing.
• Pulse Laser Enabled (output) – this output becomes active once pulsing is enabled. This may be used to

activate an indicator LED as an example.

Pulse Laser (input) – Once pulse is enabled, an inactive-active transition on this input will pulse the laser.

A momentary push-button may be used to generate this transition. The transition must appear within two

seconds after pulsing is enabled or pulsing becomes disabled and will need to be enabled again.