setup and OperatiOn

3-22

Hypertherm Fiber Laser

Instruction Manual – 807090 Revision 3

Nozzle extension at 18 mm

Nozzle

extension

scale

Indicator

mark

The calibration will fail if the controller does not detect a large enough voltage change, between the 0 mm and 18 mm

nozzle extension positions.

Continued from the previous page

Calibration

result

Push to Select

+

=

Push to Select

+

=

If the calibration was successful, the following message is displayed. The parameters will vary slightly for each system.

If there was a calibration error, the following message is displayed.

Nozzle

extension

screen 2

Move Nozzle Extension to 18 mm
Push Rotary Wheel when at position

Nozzle Position Calibration Complete
Scale Factor = 553
Push select to accept new value

Calibration Error! Loading Defaults
Scale Factor = 500
Push select to accept new value

Move Nozzle Extension to 18 mm
Push Rotary Wheel when at position

Move Nozzle Extension to 0 mm
Push Rotary Wheel when at position