troubleshoot the nozzle extension calibration

Nozzle extension calibration must detect at least two volts from 0 mm to 18 mm. This can be verified using LHC

diagnostic display. The Noz Pos variable displays the nozzle position voltage. If there is < 2 volt change in the voltage

during calibration:

1. Check the head for proper grounding.
2. Check, and if necessary, replace the cable or connector on the 12-pin cable (223169) between the LHC and

the laser head.

3. Cycle power to the laser power supply and try calibration again.

If these steps do not correct the problem, the laser head requires factory service, or the system must be operated using

manual nozzle positioning until factory service is possible.

troubleshoot CHS calibration errors

The CHS calibration routine in the laser head controller must detect a change of at least 2.5 volts from 1 mm to 10 mm.

To verify that the CHS sensor is producing an accurate voltage:

1. Navigate to the LHC diagnostic screen for AIN. RAW CHS is displayed in counts and a change in position

from 1 mm to 10 mm must be greater than a 820-count difference.

2. If this is not the case, check the head for proper grounding.
3. Check, and if necessary, replace the cable or connector on the 12-pin cable between the LHC and the laser

head.

Cycle power to laser power supply and try calibration again. If these steps do not correct the problem, the laser head

requires factory service, or the system must be operated using manual height control until factory service is possible.