beautypg.com

Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 77

background image

InstallatIon

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

2-29

1. Remove the Proximity sensor before installing the collimator.

a. Verify that the the focusing lens is not installed in the laser head
b. Remove the collimator proximity sensor from the laser head adaptor flange by loosening the mounting bolt

with a 2.5mm hex wrench and then sliding the proximity sensor out from under it. Refer to the picture

below for the location of the proximity sensor and mounting bolt. Retighten the proximity sensor mounting

bolt after removing the proximity sensor.Remove the laser head adaptor flange from the laser head

mounting bracket by removing the three adaptor flange mounting bolts (shown above).

2. Inspect the threads in the center hole of the laser head adaptor flange for any dirt or debris and clean them if

necessary.

3. Remove the collimator from the original packaging.
4. Inspect the outside of the collimator for any dust or debris before proceeding. If any dust or debris is present,

use clean dry compressed air or a lens cleaning tissue to remove it.

Adaptor flange

mounting bolts

Proximity sensor

mounting bolt

Proximity sensor

Laser head

adaptor flange

Center hole threads

Laser head

mounting bracket

The collimator is shipped in the same box as the LF150 laser head and the head accessory kit

Collimator