InstallatIon
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
2-29
1. Remove the Proximity sensor before installing the collimator.
a. Verify that the the focusing lens is not installed in the laser head
b. Remove the collimator proximity sensor from the laser head adaptor flange by loosening the mounting bolt
with a 2.5mm hex wrench and then sliding the proximity sensor out from under it. Refer to the picture
below for the location of the proximity sensor and mounting bolt. Retighten the proximity sensor mounting
bolt after removing the proximity sensor.Remove the laser head adaptor flange from the laser head
mounting bracket by removing the three adaptor flange mounting bolts (shown above).
2. Inspect the threads in the center hole of the laser head adaptor flange for any dirt or debris and clean them if
necessary.
3. Remove the collimator from the original packaging.
4. Inspect the outside of the collimator for any dust or debris before proceeding. If any dust or debris is present,
use clean dry compressed air or a lens cleaning tissue to remove it.
Adaptor flange
mounting bolts
Proximity sensor
mounting bolt
Proximity sensor
Laser head
adaptor flange
Center hole threads
Laser head
mounting bracket
The collimator is shipped in the same box as the LF150 laser head and the head accessory kit
Collimator