InstallatIon

2-2

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

Installation requirements

All installation and service of the electrical and plumbing systems must conform to national and local

electrical and plumbing codes. this work should be performed only by qualified, licensed personnel.
Direct any technical questions to the nearest Hypertherm Technical Service Department listed in the front of this manual,

or your authorized Hypertherm distributor.

Noise levels

Acceptable noise levels as defined by national and local codes may be exceeded by this laser system. Always wear

proper ear protection when cutting. Any noise measurements taken are dependant on the specific environment in which

the system is used. See also Noise can damage hearing in the Safety section of this manual. Specific information by

product can be found in the Hypertherm downloads library at:
https://www.hypertherm.com/Xnet/library/DocumentLibrary.jsp
Select the product you are looking for from the Product Type drop down menu, choose “Regulatory” from the Category

drop down menu, and choose “Acoustical Noise Data Sheets” from the Sub Category drop down menu. Hit Submit.

Placement of system components

• Place all system components in position prior to making electrical, gas, and interface connections. Use the

diagram in this section for component-placement guidelines.

• Ground all system components to earth. See Recommended grounding and shielding practices in this section

for details.

• To prevent leaks in the system, tighten all gas and water connections as shown below:

torque specifications

Gas or water

hose size

kgf – cm

lbf – in

lbf – ft

Up to 10 mm (3/8 in)

8.6 – 9.8

75 – 85

6.25 – 7

12 mm (1/2 in)

41.5 – 55

360 – 480

30 – 40