5. Carefully remove the protective caps from both ends of the collimator and inspect the inside of the collimator for

any dust, debris, or filmy residue. If any dust, debris, or residue is present the collimator must be inspected and

cleaned by properly trained personnel before use.

6. Reinstall the clear protective cap onto the input end of the colimator.
7. Hold the collimator in a vertical position with the clear protective cap

pointing up and carefully install the laser head adaptor flange onto

the collimator by threading it onto the collimator as shown below.

Turn the adaptor flange by hand until tight.

Note 1: When the flange is properly installed onto the collimator the threads on the collimator extend slightly

beyond the bottom of the flange. See the figure above.

8. Verify that the locking ring on the top of collimator is in the unlocked position. The locking ring is in the unlocked

position when the red dots are aligned.

Laser head adaptor flange

Collimator threads

Red dots