setup and OperatiOn

3-6

Hypertherm Fiber Laser

Instruction Manual – 807090 Revision 3

H

2

O valve

The laser power controller uses an electrically-actuated valve to control the water flow into the cabinet. This valve is

turned off if the system has been in the beam OFF state for 15 minutes or if a leak has been detected. This ensures that

there is no condensation on the water cooled components of the system. The valve is turned ON whenever the laser

beam is on. When the H

2

O valve is open the “Remote Chiller Run” contacts are closed. See the drawing below for an

example of the recommended circuit.

Remote chiller run

B6

B7

LPC2

LPC2

Closed when the H

2

O valve is open

Open when the H

2

O valve is closed

Flow meters

The system contains three flow meters to monitor coolant flow. If the input flow is outside its operating range, the system

goes to the fault state and disables the laser beam. If a cut is in progress and the system temperatures are within range,

the system is allowed to finish the cut before going to the fault state.

If the flow to the fiber-to-fiber coupler is outside its operating range, the system goes to the fault state and turns off the

laser beam.

If the process fiber flow is outside its operating range, the system enters the fault state.

Fiber-to-fiber coupling unit

If the fiber-to-fiber coupling unit detects excessive humidity, the system will enter the fault state and disable the laser

beam. The fiber-to-fiber coupling unit is part of the hardware in the Beam Delivery Optical circuit. If the input or output

fiber resistance is outside the specified operating range, the circuit will drop the laser power supply contacts and the

system will enter the fault state.