Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 218

Maintenance
4-26
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
DIN Status 20 – 31
DIN 20
PTL Enb
On = Pointing laser active
Off = Pointing laser inactive
Hypernet ON = CNC virtual value
DIN 21
Pulse Mode
On = Pulsing active
Off = Pulsing Inactive
Hypernet ON = CNC virtual value
DIN 22
SideJet
On = SideJet Active
Off = SideJet inactive
Hypernet ON = CNC virtual value
DIN 23
Flt Reset
On = Fault reset active
Off = Fault reset inactive
Hypernet ON = CNC virtual value
DIN 24
DIN24
On = Input active
Off = Input inactive
DIN 25
Field Pwr
On = Laser system field 24VDC OK
Off = Laser system field 24VDC low
DIN 26
AIR Sel
On = Air process gas
Off = 0
2
process gas
Hypernet ON = CNC virtual value
DIN 27
N
2
Sel
On = Nitogen process gas
Off = ---0
2
or AIR process gas
Hypernet ON = CNC virtual value
DIN 28
FCU Flw
Flt = Fiber Coupling Unit flow rate below minimum
DIN 29
DIN29
On = Input active
Off = Input inactive
DIN 30
Fiber OK A
On = Delivery Fiber Interlock Circuit OPEN
Off = Delivery Fiber Interlock Circuit CLOSED
DIN 31
Fiber OK B
On = Delivery Fiber Interlock Circuit OPEN
Off = Delivery Fiber Interlock Circuit CLOSED