background image

Maintenance

4-26

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

DIN Status 20 – 31
DIN 20

PTL Enb

On = Pointing laser active

Off = Pointing laser inactive

Hypernet ON = CNC virtual value

DIN 21

Pulse Mode

On = Pulsing active

Off = Pulsing Inactive

Hypernet ON = CNC virtual value

DIN 22

SideJet

On = SideJet Active

Off = SideJet inactive

Hypernet ON = CNC virtual value

DIN 23

Flt Reset

On = Fault reset active

Off = Fault reset inactive

Hypernet ON = CNC virtual value

DIN 24

DIN24

On = Input active

Off = Input inactive

DIN 25

Field Pwr

On = Laser system field 24VDC OK

Off = Laser system field 24VDC low

DIN 26

AIR Sel

On = Air process gas

Off = 0

2

process gas

Hypernet ON = CNC virtual value

DIN 27

N

2

Sel

On = Nitogen process gas

Off = ---0

2

or AIR process gas

Hypernet ON = CNC virtual value

DIN 28

FCU Flw

Flt = Fiber Coupling Unit flow rate below minimum

DIN 29

DIN29

On = Input active

Off = Input inactive

DIN 30

Fiber OK A

On = Delivery Fiber Interlock Circuit OPEN

Off = Delivery Fiber Interlock Circuit CLOSED

DIN 31

Fiber OK B

On = Delivery Fiber Interlock Circuit OPEN

Off = Delivery Fiber Interlock Circuit CLOSED