beautypg.com

Troubleshooting routines, Mild steel o2 cutting, Troubleshooting routines -20 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 212: Mild steel o, Cutting -20, Cutting

background image

Maintenance

4-20

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

troubleshooting routines

Mild steel O

2

cutting

Set to the closest available process

parameters.

Have you cut this

material before?

Yes

Are the

parameters set

to the cut charts or a

process used in the

past?

Over burning or excessive cut-edge roughness

Is it only present

when cutting in a certain

direction?

Correct the parameters for pressure,

assist-gas type, focal position, cut

speed, nozzle size, nozzle type,

nozzle-to-workpiece height, and laser

power.

Inspect nozzle for damage, dross

adhesion, beam centering, and

orifice condition. Clean or replace.

Yes

Is the problem

corrected?

Decrease oxygen pressure.

Inspect lens for dirt or damage.

Clean or replace.

No

Yes

Is the problem

corrected?

Is the

problem corrected?

Other possible causes:

• Poor material quality

• Poor material surface condition

• Excessive plate temperature

• Bent or damaged nozzle holder

No

Continue cutting and

record new parameters

Inspect nozzle for damage, dross

adhesion, beam centering, and orifice

condition. Clean or replace.

Is the problem

corrected?

Decrease assist gas pressure.

Adjust focal position.

Is the problem

corrected?

Is the problem

corrected?

Other possible causes:

• Poor material quality

• Incorrect oxygen purity

• Excessive plate temperature

• Contamination of collimator or fiber optics

Decrease nozzle diameter.

Is the problem

corrected?

Inspect lens for dirt or damage.

Clean or replace.

Is the problem

corrected?

Yes

Yes

Yes

No

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes