beautypg.com

System gas requirements, Gas quality and pressure requirements, System gas requirements -10 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 42: Gas quality and pressure requirements -10

background image

SpecificationS

1-10

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

System gas requirements

Caution:

5 µm filtration is required on oxygen and nitrogen

supply lines. Failure to use an acceptable filter can

cause poor cut quality and damage to the laser system.

Gas quality and pressure requirements

Gas type

Quality

Pressure +/- 10%

Flow rate

O

2

oxygen*

99.95% pure

Clean, dry, oil-free

800 kPa / 8 bar

116 psi

170 slpm 360

scfh

N

2

nitrogen*

99.5% pure

Clean, dry, oil-free

2.7 MPa / 27 bar

400 psi

1600 slpm

3400 scfh

Air*

** Clean, dry, oil-free

per ISO 8573-1 Class 1.4.2

900 kPa / 9 bar

130 psi

***250 slpm

530 scfh

* Oxygen, nitrogen, and air are required to be connected at all times

** ISO standard 8573-1 Class 1.4.2 requirements are:

• Particulates – no more than 100 particles per cubic meter of air at a size of 0.1 to 0.5 microns in the largest

dimension and 1 particle per cubic meter of air at a size of 0.5 to 5.0 microns in the largest dimension.

• Water – the pressure dew point of the humidity must be less than or equal to 3° C (37.4° F).
• Oil – the concentration of oil can be no more than 0.1 mg per cubic meter of air.

*** If air will not be used as a cut gas, the required pressure and flow rate of the air supply can be reduced:

• Pressure: 500 kPa / 5 bar / 75 psi
• Flow rate: 25 slpm / 53 scfh