System gas requirements, Gas quality and pressure requirements, System gas requirements -10 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 42: Gas quality and pressure requirements -10
SpecificationS
1-10
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
System gas requirements
Caution:
5 µm filtration is required on oxygen and nitrogen
supply lines. Failure to use an acceptable filter can
cause poor cut quality and damage to the laser system.
Gas quality and pressure requirements
Gas type
Quality
Pressure +/- 10%
Flow rate
O
2
oxygen*
99.95% pure
Clean, dry, oil-free
800 kPa / 8 bar
116 psi
170 slpm 360
scfh
N
2
nitrogen*
99.5% pure
Clean, dry, oil-free
2.7 MPa / 27 bar
400 psi
1600 slpm
3400 scfh
Air*
** Clean, dry, oil-free
per ISO 8573-1 Class 1.4.2
900 kPa / 9 bar
130 psi
***250 slpm
530 scfh
* Oxygen, nitrogen, and air are required to be connected at all times
** ISO standard 8573-1 Class 1.4.2 requirements are:
• Particulates – no more than 100 particles per cubic meter of air at a size of 0.1 to 0.5 microns in the largest
dimension and 1 particle per cubic meter of air at a size of 0.5 to 5.0 microns in the largest dimension.
• Water – the pressure dew point of the humidity must be less than or equal to 3° C (37.4° F).
• Oil – the concentration of oil can be no more than 0.1 mg per cubic meter of air.
*** If air will not be used as a cut gas, the required pressure and flow rate of the air supply can be reduced:
• Pressure: 500 kPa / 5 bar / 75 psi
• Flow rate: 25 slpm / 53 scfh