beautypg.com

Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 213

background image

Maintenance

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

4-21

Set to the closest available process

parameters.

Have you cut this

material before?

Yes

Are the

parameters set to the

cut charts or a process

used in the past?

Dross on mild steel

Is the dross

hard and shiny?

Correct the parameters for pressure,

assist-gas type, focal position, cut

speed, nozzle size, nozzle type, nozzle-to-

workpiece height, and laser power.

Increase oxygen pressure.

Yes

Is the problem corrected?

Decrease cutting speed.

Adjust focal position.

No

Yes

Is the problem corrected?

Is the problem corrected?

Other possible causes:

• Poor material quality

• Incorrect oxygen purity

No

Continue cutting and

record new parameters

Inspect nozzle for damage, dross

adhesion, beam centering, and orifice

condition.

Clean or replace.

Is the dross brittle and

porous?

Decrease assist gas pressure.

Decrease nozzle diameter.

Is the problem corrected?

Is the problem corrected?

Other possible causes:

• Poor material quality

• Incorrect oxygen purity

• Excessive plate temperature

• Contamination of collimator or

fiber optics

Adjust focal position.

Inspect lens for dirt or damage.

Clean or replace.

Yes

No

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Inspect lens for dirt or damage.

Clean or replace.

Is the problem corrected?

No

Yes

Is the problem corrected?

Is the problem corrected?

Is the problem corrected?