Generic cnc, Generic cnc -16 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 48
SpecificationS
1-16
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
Generic CNC
Z axis lifter
• Modified to allow mounting of fiber laser head bracket
• Capable of moving fiber laser head (7.8 kg / 17.2 lbs)
CNC I/O interface
Physical connectors: Phoenix contact part numbers 1772405 and 1772418
CNC digital outputs (0-24 VDC sourcing opto-isolators from CNC to laser controller, 24 VDC = active [on])
Fault acknowledge/reset (rising edge triggered) ..........................................................Required
Digital beam ...........................................................................................................................Required
Pointing laser enable ...........................................................................................................Required
Corner power pulsing enable ............................................................................................Optional
Side jet ....................................................................................................................................Optional
Air select (off = O
2
, on = air) ............................................................................................Required
N
2
select .................................................................................................................................Required
CNC digital inputs (Normally Open [NO] isolated 24 VDC relay contacts from laser controller to the CNC)
Laser fault ...............................................................................................................................Required
Pointing laser status ............................................................................................................Optional
Laser head fault ....................................................................................................................Required
Nozzle contact .......................................................................................................................Required
Over range (>10 mm) ..........................................................................................................Optional
Gas control fault ...................................................................................................................Required
CNC analog outputs to laser controller (0 – 10 VDC)
Laser power set point (0 – maximum output power in watts) ....................................Required
Corner power (duty cycle) set point (1 – 99%) ............................................................Optional
Assist gas pressure set point ............................................................................................Required
(Air/O
2
= 0 – 130 psi, N
2
= 0 – 500 psi)
CNC analog input from laser controller (0 – 10 VDC)
Capacitive height sensor voltage (scaling 1 volt per mm) ..........................................Required for auto height control