Status Message
Description
Safety Relay Interlock Fault
Safety relay is off (the safety circuit is in the open state)
Contactor 1 Fault
Safety contactor 1 malfunction
Contactor 2 Fault
Safety contactor 2 malfunction
Interlock Circuit 1 is Open
Front door of laser power control unit is open
Interlock Circuit 2 is Open
Rear door of laser power control unit is open
Delivery Fiber BDO-1 Fault
Fiber BDO interlock circuit malfunction
Delivery Fiber BDO-2 Fault
Fiber BDO interlock circuit malfunction
Fiber Combiner Fault
Combiner optical power sensor limit exceeded
Laser Supply Temperature Fault
Power supply temperature limit exceeded
Laser Supply Current Fault
Power supply current limit exceeded
24VDC Field Supply Fault
Laser controller field supply voltage out of range
Lens Door Open Fault
Laser head lens door is open
Head Collision Fault
Laser head collision
Laser Head Faulted
Laser Head is being calibrated or has an active fault
CNC Protocol Mismatch
Incompatible Pheonix version detected. Must upgrade pheonix to
9.72.2 or higher.
Ethernet Cable Disconnected
The ethernet cable is disconnected from Laser Power Controller
inside the laser power supply, or the ethernet switch is not
working.
CNC Communications Timeout
CNC communications error
LHC Communications Timeout
Laser head controller communications error
LPC Communications Timeout
Laser power controller communications error
Module 1 Low Power Error
Laser module 1 not producing expected output power. Latches
after 3rd occurance. System should not be operated at full power
until factory consultation. Permanent Laser damage could result
Module 2 Low Power Error
Laser module 2 not producing expected output power. Latches
after 3rd occurance. System should not be operated at full power
until factory consultation. Permanent Laser damage could result
Module 3 Low Power Error
Laser module 3 not producing expected output power. Latches
after 3rd occurance. System should not be operated at full power
until factory consultation. Permanent Laser damage could result
Module 4 Low Power Error
Laser module 4 not producing expected output power. Latches
after 3rd occurance. System should not be operated at full power
until factory consultation. Permanent Laser damage could result
Module 5 Low Power Error
Laser module 5 not producing expected output power. Latches
after 3rd occurance. System should not be operated at full power
until factory consultation. Permanent Laser damage could result
Module 6 Low Power Error
Laser module 6 not producing expected output power. Latches
after 3rd occurance. System should not be operated at full power
until factory consultation. Permanent Laser damage could result