Calibration

Nozzle position calibration

The nozzle position calibration is a two-point calibration to adjust the position feedback for the nozzle position. Nozzle

calibration should be performed at installation and any time that cut quality decreases.

To begin calibration verify that the main menu (shown below) is displayed on the laser head controller screen and follow

the steps outlined below.

Nozzle extension at 0 mm

Continued on the next page

Push to Select

+

=

Configuration

screen

Push to Select

+

=

Calibration

screen

Push to Select

+

=

Nozzle

extension

screen 1

Rotate the nozzle extension until it is fully retracted to the main

body of

the cutting head.

LHC Ver: 1.13

LPC Ver: 1.17 P2

Laser power 1500W

O2

12 PSI

Beam

OFF System

OK

Calibrate Nozzle Position
Calibrate CHS Position

Move Nozzle Extension to 0 mm

Push Rotary Wheel when at position