Diagnostics screen navigation, Diagnostics screen navigation -15 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 123

setup and OperatiOn
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
3-15
Push to Select
+
=
Configuration
screen
Push to Select
+
=
Diagnostics
screen
Diagnostics screen navigation
Note: The process shown below can also be followed to verify the parameters in the LHC SERVICE MODE by
choosing “more” after verifying the LPC parameters.
Verify the LPC parameters on the screen shown above by comparing them with the data in the LPC service mode
parameters tables at the end of section 4, Maintenance, of this manual. Verify the LHC parameters by comparing the
values shown on the LHC diagnostics parameters screen with the data in the LHC diagnostic parameters tables at the
end of section 4, Maintenance, of this manual.
Push to Select
+
=
LPC SERVICE
MODE screen
Push to Select
+
=
LPC
parameters
screen
LHC Ver: 1.13
LPC Ver: 1.17 P2
LPC SERVICE MODE
DIN Status
DOUT Status
AIN Status
AOUT Status
LPC SERVICE MODE
DIN 0-7
AIN 8-15
DOUT 16-23
AOUT 24-31
PS Flt
Off
PF Flw
Off
DR Int1
Off
Safe Rly
Off
DR Int2
Off
Cont1
Off
FCU Leak
Off
Cont2
Off
Laser power 1500W
O2
12 PSI
Beam ON
System OK