Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 79

InstallatIon
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
2-31
Caution:
Lint and powder free gloves must be worn for the remainder of this
procedure to prevent damage to optical surfaces
9. Put on lint and powder free gloves for the remainder of this procedure.
10. Visually inspect the outside of the bayonet connector on the Beam delivery optical cable for any dust or debris
before proceeding. If any dust or debris exists, use clean dry compressed air or a lens cleaning tissue to remove
it.
11. Carefully remove the black protective cap from the Beam delivery optical cable and visually inspect the quartz
block for any dust, debris or filmy residue. If any dust, debris or filmy residue is present the Beam delivery optical
cable must be cleaned by properly trained personnel before using. Reference the “Cleaning the quartz block”
in the maintenance section of the Fiber Laser Instruction manual for additional information. Reinstall the black
protective cap on the Beam delivery optical cable after inspection or cleaning.
12. With the help of an assistant, hold the bayonet connector of the Beam delivery optical cable in a horizontal
position and carefully remove the black protective cap.
13. With the help of an assistant, hold the collimator in a horizontal position and carefully remove the clear
protective cap from the input end.
14. Insert the clear protective cap into the black protective cap (shown below) and place these into the Head
Accessory kit for future use.
15. Locate the red alignment dots on the bayonet
and the collimator. Rotate the collimator to align
the red dots as shown and carefully insert the
bayonet into the collimator and turn the locking
ring clockwise to lock the devices together.
Clear protective cap
Black protective cap