beautypg.com

Specifications, Fiber laser supply, Overview – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 33: Specifications -1, Fiber laser supply -1, Overview -1

background image

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

1-1

Section 1

SPECIFICAtIONS

Fiber laser supply

Overview

The HyIntensity Fiber Laser (HFL) is a laser system based on all solid state components. The fiber laser supply contains

two to six laser engines and a beam combiner unit. Incoming electricity is converted to optical power by single emitter

based pump laser diodes in each engine, which is converted to a high brightness infrared (non-visible) laser beam.

Light from each of the laser engines enters the beam combiner unit which funnels the light into a single output fiber.

This configuration has a wall plug electrical to optical output power efficiency greater than 28%. All of the optical

components are water cooled to provide stable operation. A dehumidifier in the fiber laser supply maintains the humidity

level inside the cabinet enclosure.

Fiber laser supplies
Part number

Description

051041

HFL010 — 1.0 kW fiber laser supply, with the fiber coupling unit, 400-480 VAC, 50/60 Hz

051042

HFL010 — 1.0 kW fiber laser supply, without the fiber coupling unit, 400-480 VAC, 50/60 Hz

051023

HFL015 — 1.5 kW fiber laser supply, with the fiber coupling unit, 400-480 VAC, 50/60 Hz

051043

HFL015 — 1.5 kW fiber laser supply, without the fiber coupling unit, 400-480 VAC, 50/60 Hz

051039

HFL020 — 2.0 kW fiber laser supply, with the fiber coupling unit, 400-480 VAC, 50/60 Hz

051044

HFL020 — 2.0 kW fiber laser supply, without the fiber coupling unit, 400-480 VAC, 50/60 Hz

051048

HFL030 — 3.0 kW fiber laser supply, with the fiber coupling unit, 440-480 VAC 50/60 Hz

051053

HFL030 — 3.0 kW fiber laser supply, without the fiber coupling unit, 440-480 VAC 50/60 Hz

051049

HFL030 — 3.0 kW fiber laser supply, with the fiber coupling unit, 380-400 VAC 50/60 Hz

051052