Gas control console – 051024, Overview, Gas control console – 051024 -12 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 44: Overview -12, Specifications 1-12
SpecificationS
1-12
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
Gas control console – 051024
Overview
The gas console manages the selection of the cut gas and sets its pressure. It also sets the flow rate/pressure of the
air supplied to the purge and side-jet ports of the laser head. It contains proportional valves, solenoid valves, pressure
transducers, hoses and fittings necessary to perform these functions.
• The maximum recommended length for supply hoses from the gas supply to the gas console is 50 m (150 ft).
• The minimum recommended inner diameter (ID) of the air and oxygen supply hoses is 10 mm (3/8 in).
• The minimum recommended ID of the nitrogen supply hose is 12 mm (1/2 in).
• The maximum hose length from the gas console to the laser head is 10 m (33 ft).
• The maximum cable length from the gas console to the laser head controller is 10 m (33 ft)
Fitting
Size
Air
1/4 in BSPT (female)
Oxygen (O
2
)
and
nitrogen (N
2
)
1/4 in NPT (female)
Side jet
1/8 in NPT (female)
Purge
1/8 in NPT (female)
Cut gas
1/4 in NPT (female)
13.0 kg
29.0 lb
63.5 mm
2.5 in
6.731 mm
0.265 in
(4 places)
203.2 mm
8.0 in
460.375 mm
18.125 in
434.77 mm
17.18 in
266.7 mm
10.5 in
473.3 mm
18.64 in
238.2 mm
9.38 in