background image

setup and OperatiOn

3-12

Hypertherm Fiber Laser

Instruction Manual – 807090 Revision 3

Navigating the Display Screen

There are three sets of information shown on the laser head controller display:

• The Main display screen provides status information about the fiber laser system.
• The configuration display screen allows the user to enter the set-ups, diagnostics, or calibration screens.
• The Diagnostics display screen provides status of system inputs and outputs for troubleshooting.

The display shows up to four lines at a time. The large knob (selection knob) below the LCD display allows you to scroll

up and down through each display.

Descriptions of the fields on the main display screen

Changing the value of a parameter:

1. Rotate the selection knob to scroll to the parameter. The active parameter flashes.
2. Push the selection knob to select the parameter.
3. Rotate the selection knob to scroll through the value options for that parameter.
4. Push the selection knob when you have selected the appropriate option.

Note: The value reverts to the original entry if a new value is not selected in 5 seconds.

• Select to return to the previous screen.
• Select to advance to the next screen.
• The Setup Screen can be accessed by pressing the rotary wheel when the beam is off.

Selection knob

Push to Select

(Laser power)

(PWM display option)

(Gas selection)

(Output pressure)

(System state)

(System status)

(System warning)