DIN Status 0 – 19
DIN 0
PS Flt
On = Power supply faulted
Off = Power supply OK
DIN 1
DR INT1
On = Front cabinet door open
Off = Front cabinet door closed
DIN 2
DR INT2
On = Rear cabinet door open
Off = Rear cabinet door closed
DIN 3
FCU Leak
Flt = Leak detected in fiber coupling unit
DIN 4
PF Flw
Flt = Flow rate out of range for the process fiber
DIN 5
Safe Rly
On = Safety circuit open
Off = Safety circuit closed
DIN 6
Cont1
On = Power supply contactor 1 active
Off = Power supply contactor 1 inactive
DIN 7
Cont2
On = Power supply contactor 2 active
Off = Power supply contactor 2 inactive
DIN 8
Cur Lim1
On = Laser module 1 current limit fault
Off = Laser module 1 current limit in range
DIN 9
Cur Lim2
On = Laser module 2 current limit fault
Off = Laser module 2 current limit in range
DIN 10
Cur Lim3
On = Laser module 3 current limit fault
Off = Laser module 3 current limit in range
DIN 11
Cur Lim4
On = Laser module 4 current limit fault
Off = Laser module 4 current limit in range
DIN 12
DIN12
On = Input active
Off = Input inactive
DIN 13
DIN13
On = Input active
Off = Input inactive
DIN 14
DIN14
On = Input active
Off = Input inactive
DIN 15
DIN15
On = Input active
Off = Input inactive
DIN 16
DIN16
On = Input active
Off = Input inactive
DIN 17
Leak
Flt = Cabinet leak detected
DIN 18
H20 Flw
Flt = Input water flow rate out of range
DIN 19
Beam On
Hypernet OFF = Digital beam enable input is displayed
Hypernet ON = Virtual beam on state from CNC
LPC service mode parameters
Note: The following I/O points automatically change to “vrtual” I/O points when an EdgePro CNC is used in the
cutting system: DIN19 through DIN23, DIN26, and DIN27. This allows users to validate values sent from
the CNC over Hypernet.