Maintenance

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

4-25

DIN Status 0 – 19
DIN 0

PS Flt

On = Power supply faulted

Off = Power supply OK

DIN 1

DR INT1

On = Front cabinet door open

Off = Front cabinet door closed

DIN 2

DR INT2

On = Rear cabinet door open

Off = Rear cabinet door closed

DIN 3

FCU Leak

Flt = Leak detected in fiber coupling unit

DIN 4

PF Flw

Flt = Flow rate out of range for the process fiber

DIN 5

Safe Rly

On = Safety circuit open

Off = Safety circuit closed

DIN 6

Cont1

On = Power supply contactor 1 active

Off = Power supply contactor 1 inactive

DIN 7

Cont2

On = Power supply contactor 2 active

Off = Power supply contactor 2 inactive

DIN 8

Cur Lim1

On = Laser module 1 current limit fault

Off = Laser module 1 current limit in range

DIN 9

Cur Lim2

On = Laser module 2 current limit fault

Off = Laser module 2 current limit in range

DIN 10

Cur Lim3

On = Laser module 3 current limit fault

Off = Laser module 3 current limit in range

DIN 11

Cur Lim4

On = Laser module 4 current limit fault

Off = Laser module 4 current limit in range

DIN 12

DIN12

On = Input active

Off = Input inactive

DIN 13

DIN13

On = Input active

Off = Input inactive

DIN 14

DIN14

On = Input active

Off = Input inactive

DIN 15

DIN15

On = Input active

Off = Input inactive

DIN 16

DIN16

On = Input active

Off = Input inactive

DIN 17

Leak

Flt = Cabinet leak detected

DIN 18

H20 Flw

Flt = Input water flow rate out of range

DIN 19

Beam On

Hypernet OFF = Digital beam enable input is displayed

Hypernet ON = Virtual beam on state from CNC

LPC service mode parameters

Note: The following I/O points automatically change to “vrtual” I/O points when an EdgePro CNC is used in the

cutting system: DIN19 through DIN23, DIN26, and DIN27. This allows users to validate values sent from

the CNC over Hypernet.