Lpc 2, Lpc 2 -32 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 224

Maintenance
4-32
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
Pin
Signal
A-1
External door interlock NO Contact 1
3
A-2
External door interlock NO Contact 2
3
A-3
External start/reset switch indicator +
3
A-4
Keyswitch contact
3
A-5
External green stack light output_A
1
A-6
External yellow stack light output_A
1
A-7
External red stack light output_A
1
A-8
Oxygen/air select input
3
A-9
Laser head controller power (+24 VDC)
B-2
NC
B-3
NC
B-4
Field common
B-5
Field common
B-6
Chiller remote start
B-7
Chiller remote start
B-8
NC
C-1
External E-Stop switch NO contact 1
3
C-2
External E-Stop switch NO contact 2
3
C-3
External start/reset switch indicator
3
C-4
Start/reset momentary switch
3
C-5
External green stack light output_B
2
C-6
External yellow stack light output_B
2
C-7
External red stack light output_B
2
C-8
Nitrogen select input
2
C-9
Laser head controller power (common)
LPC 2
Part
Part number
Mating connector
108944
22-24 AWG pins
108948
18 AWG pins
108947
Connector housing
108941
Cable strain relief
108942
Crimp tool made by
Phoenix Contact
1687419
Notes:
1
These discrete outputs are dry relay contacts (5 – 24 VDC @ 0.2 Amps)
2
These discrete inputs require a positive voltage (12 – 34 VDC) to activate the input
3
Reference the Electrical diagram for external safety switches in the Installation section of this manual