Status Message

Description

System OK

No active faults

Module 1 ColdPlate Over Temp

Laser module 1 input cold plate exceeds 40° C

Module 1 Output Over Temp

Laser module 1 output cold plate exceeds 40° C

Module 1 Over Current

Laser module 1 over current fault

(must cycle power to laser power cabinet to reset)

Module 1 Output Power Error

Laser module 1 power output exceeds 600 watts

Module 2 ColdPlate Over Temp

Laser module 2 input cold plate exceeds 40° C

Module 2 Output Over Temp

Laser module 2 output cold plate exceeds 40° C

Module 2 Over Current

Laser module 2 over current fault

(must cycle power to laser power cabinet to reset)

Module 2 Output Power Error

Laser module 2 power output exceeds 600 watts

Module 3 ColdPlate Over Temp

Laser module 3 input cold plate exceeds 40° C

Module 3 Output Over Temp

Laser module 3 output cold plate exceeds 40° C

Module 3 Over Current

Laser module 3 over current fault

(must cycle power to laser power cabinet to reset)

Module 3 Output Power Error

Laser module 3 power output exceeds 600 watts

Module 4 ColdPlate Over Temp

Laser module 4 input cold plate exceeds 40° C

Module 4 Output Over Temp

Laser module 4 output cold plate exceeds 40° C

Module 4 Over Current

Laser module 4 over current fault

(must cycle power to laser power cabinet to reset)

Module 4 Output Power Error

Laser module 4 power output exceeds 600 watts

Module 5 ColdPlate Over Temp

Laser module 5 input cold plate exceeds 40° C

Module 5 Output Over Temp

Laser module 5 output cold plate exceeds 40° C

Module 5 Over Current

Laser module 5 over current fault

(must cycle power to laser power cabinet to reset)

Module 5 Output Power Error

Laser module 5 power output exceeds 600 watts

Module 6 ColdPlate Over Temp

Laser module 6 input cold plate exceeds 40° C

Module 6 Output Over Temp

Laser module 6 output cold plate exceeds 40° C

Module 6 Over Current

Laser module 6 over current fault

(must cycle power to laser power cabinet to reset)

Module 6 Output Power Error

Laser module 6 power output exceeds 600 watts

Primary Coolant Flow fault

Input water flow rate below minimum setpoint

Laser Supply Fault

DC power Supply fault due to Low line voltage

Bad Software Setup Parameter

Flash memory error defaults loaded

Process Fiber Coolant Fault

Process fiber flow rate below minimum setpoint

FCU Manifold Coolant Fault

Fiber to fiber coupling unit flow rate below minimum setpoint

Fiber-Fiber Leak Detected

Leak detected inside the fiber to fiber coupling unit

Cabinet Leak Detected

Water leak detected in the laser power controller unit

LHC error messages

NOTE: module 5 and 6 errors are for the HFL030 only