Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 132

setup and OperatiOn
3-24
Hypertherm Fiber Laser
Instruction Manual – 807090 Revision 3
10 mm nozzle to workpiece distance
Feeler gauge
1 mm nozzle to workpiece distance
Position the cutting head over the material, away from the edges of the material, and move it down until the calibration
feeler gauge rubs on the material and nozzle and the Tip Touch Indicator illuminates on the laser head controller. Avoid
pressing down on the material and causing deflection and inaccuracies in the calibration.
When the 1 mm height is correct, remove the feeler gauge, and push the thumb wheel to set calibration height 1.
Continued from the previous page
After the 1 mm calibration point is set the following screen will be displayed.
Position the cutting head over the material, away from the edges of the material, and move it down until the calibration
feeler gauge rubs on the material and nozzle and the Tip Touch Indicator illuminates on the laser head controller. Avoid
pressing down on the material and causing deflection and inaccuracies in the calibration.
When the 10 mm height is correct, remove the feeler gauge, and push the thumb wheel to set calibration height 2.
Continued on the next page
Move Head to 10 mm
Push Rotary Wheel when at position