beautypg.com

Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 132

background image

setup and OperatiOn

3-24

Hypertherm Fiber Laser

Instruction Manual – 807090 Revision 3

10 mm nozzle to workpiece distance

Feeler gauge

1 mm nozzle to workpiece distance

Position the cutting head over the material, away from the edges of the material, and move it down until the calibration

feeler gauge rubs on the material and nozzle and the Tip Touch Indicator illuminates on the laser head controller. Avoid

pressing down on the material and causing deflection and inaccuracies in the calibration.
When the 1 mm height is correct, remove the feeler gauge, and push the thumb wheel to set calibration height 1.

Continued from the previous page

After the 1 mm calibration point is set the following screen will be displayed.

Position the cutting head over the material, away from the edges of the material, and move it down until the calibration

feeler gauge rubs on the material and nozzle and the Tip Touch Indicator illuminates on the laser head controller. Avoid

pressing down on the material and causing deflection and inaccuracies in the calibration.
When the 10 mm height is correct, remove the feeler gauge, and push the thumb wheel to set calibration height 2.

Continued on the next page

Move Head to 10 mm
Push Rotary Wheel when at position