beautypg.com

Adjust side jet pressure, Adjust side jet pressure -36 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 144

background image

setup and OperatiOn

3-36

Hypertherm Fiber Laser

Instruction Manual – 807090 Revision 3

Adjust side jet pressure

For cutting mild steel thicker than 3 mm, the side jet quickly clears molten material from the pierce location and helps

create clean pierce holes. An optimum pressure setting for the side jet is critical. If the pressure is too low, the molten

material is not effectively cleared and the pierce hole can be too large. If the pressure is too high, the oxygen in the side

jet can cause uncontrolled burning at the pierce location and the pierce hole may be too large. The side jet gas pressure

can be increased or decreased by turning the pressure regulator clockwise or counter clockwise respectively.

• Pull the pressure regulator knob to unlock. An orange

mark appears in the gap when the pressure regulator

knob is unlocked.

• Turn the knob clockwise to increase side jet pressure

or counterclockwise to decrease the side jet

pressure.

• Push the pressure regulator knob to lock. If it is

difficult to lock the knob, turn it left and right a little

and then push it again. The orange mark will no

longer be visible when the knob is locked.

Pressure

regulator

knob

Note: The side jet pressure is set to 0.3 MPa (3.0 bar, 43.5 psi) at the factory.