beautypg.com

Hyintensity fiber laser machine interface, Lpc 1, Hyintensity fiber laser machine interface -31 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual

Page 223: Lpc 1 -31

background image

Maintenance

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

4-31

Pin

Signal

A-1

Process power (analog input)

1

A-2

Analog common

A-3

Corner power (analog input)

1

A-4

Analog common

A-5

Assist gas pressure setpoint (analog input)

1

A-6

Analog common

A-7

Capacitive height sense (analog output - 1 volt/mm)

A-8

Analog common

A-9

Laser fault output_A

2

B-2

Gas fault output_A

2

B-3

Gas fault output_B

2

B-4

Digital beam enable input

3

B-5

Pointing laser enable input

3

B-6

Corner power pulsing enable input

3

B-7

Side jet enable input

3

B-8

Laser fault reset input

3

C-1

Over range output_B

2

C-2

Pointing laser status output_A

2

C-3

Pointing laser status output_B

2

C-4

Laser head fault output_A

2

C-5

Laser head fault output_B

2

C-6

Nozzle contact output_A

2

C-7

Nozzle contact output_B

2

C-8

Over range output_A

2

C-9

Laser fault output_B

2

Part

Part number

Mating connector

108945

22-24 AWG sockets

108946

Connector housing

108941

Cable strain relief

108942

Crimp tool made by

Phoenix Contact

1687419

Notes:

1

These analog inputs are 0 – 10 VDC single ended inputs

2

These discrete outputs are dry relay contacts (5 – 24 VDC @ 0.2 amps)

3

These discrete inputs require a positive voltage (12 – 34 VDC) to activate the input

HyIntensity Fiber Laser Machine Interface

Note: Go to page 4-32 to see examples of typical interface circuits.

LPC 1