Hyintensity fiber laser machine interface, Lpc 1, Hyintensity fiber laser machine interface -31 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 223: Lpc 1 -31

Maintenance
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
4-31
Pin
Signal
A-1
Process power (analog input)
1
A-2
Analog common
A-3
Corner power (analog input)
1
A-4
Analog common
A-5
Assist gas pressure setpoint (analog input)
1
A-6
Analog common
A-7
Capacitive height sense (analog output - 1 volt/mm)
A-8
Analog common
A-9
Laser fault output_A
2
B-2
Gas fault output_A
2
B-3
Gas fault output_B
2
B-4
Digital beam enable input
3
B-5
Pointing laser enable input
3
B-6
Corner power pulsing enable input
3
B-7
Side jet enable input
3
B-8
Laser fault reset input
3
C-1
Over range output_B
2
C-2
Pointing laser status output_A
2
C-3
Pointing laser status output_B
2
C-4
Laser head fault output_A
2
C-5
Laser head fault output_B
2
C-6
Nozzle contact output_A
2
C-7
Nozzle contact output_B
2
C-8
Over range output_A
2
C-9
Laser fault output_B
2
Part
Part number
Mating connector
108945
22-24 AWG sockets
108946
Connector housing
108941
Cable strain relief
108942
Crimp tool made by
Phoenix Contact
1687419
Notes:
1
These analog inputs are 0 – 10 VDC single ended inputs
2
These discrete outputs are dry relay contacts (5 – 24 VDC @ 0.2 amps)
3
These discrete inputs require a positive voltage (12 – 34 VDC) to activate the input
HyIntensity Fiber Laser Machine Interface
Note: Go to page 4-32 to see examples of typical interface circuits.
LPC 1