background image

setup and OperatiOn

HyIntensity Fiber Laser

Instruction Manual – 807090 Revision 3

3-27

4. Select Calibrate CHS on the process screen.

Laser process screen

5. Follow the instructions displayed on the screen.
6. If the maximum height detected is within a range of 0.36 in - 0.44 in (9 to 11 mm) the calibration is complete.

If the maximum height detected is outside the range, refer to Troubleshoot CHS calibration errors in the

Maintenance section of this manual.