Maintenance
4-28
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
DOUt Status 0 – 15
DOUt 0
GRN STK1
On = Cabinet green stack light ON
Off = Cabinet green stack light OFF
DOUt 1
YEL STK1
On = Cabinet yellow stack light ON
Off = Cabinet yellow stack light OFF
DOUt 2
RED STK1
On= Cabinet red stack light ON
Off = Cabinet red stack light OFF
DOUt 3
GRN STK2
On = External green stack light output contact closed
Off = External green stack light output contact open
DOUt 4
YEL STK2
On = External yellow stack light output contact closed
Off = External yellow stack light output contact open
DOUt 5
RED STK2
On = External red stack light output contact closed
Off = External red stack light output contact open
DOUt 6
PTL CMD
On = Internal pointing laser contact closed
Off= Internal pointing laser contact open
DOUt 7
CNTRL OK
On = Laser power controller OK
Off = Laser power contoller Flt
DOUt 8
LASER FLT
On = Laser fault active output contact closed
Off = Laser fault inactive output contact open
DOUt 9
PLT STATUS
On = Pointing laser on output contact closed
Off = Pointing laser off output contact open
DOUt 10
LH FLT
On = Laser head fault active output contact closed
Off = Laser head fault inactive output contact open
DOUt 11
TIPTOUCH
On = Nozzle contact active output contact closed
Off = Nozzle contact inactive output contact open
DOUt 12
LH OR
On = Overrange output active output contact closed
Off = Overrange output inactive output contact open
DOUt 13
GAS FLT
On = Gas fault output active output contact closed
Off = Gas fault output inactive output contact open
DOUt 14
PS ENB
On = Power supply interlock enabled
Off = Power supply interlock disabled
DOUt 15
H20 VALVE
On = Input water valve open
Off = Input water valve closed
AOUt Status
PS CMD
Power supply command (0 – 10 Volts = 0 to 100%)
CHS