G&D DVICenter · 81

4. Select the

USB Auto Refresh

entry and press

F8

to select the keyboard type:

5. Press

F2

to save your settings.

Enhanced functions

Setting the auto user logout

The user module can be configured so that it auto-disconnects the access to the tar-

get module after a user has been inactive for a certain amount of time. After the con-

figured period of time, the user is logged out from the matrix system.

How to set the auto user logout:
1. Press the

Ctrl+Num

(default) hotkey to open the on-screen display.

2. Press

F11

to call the Configuration menu.

3. Select the

Console

entry and press

Enter

.

4. Select the user module whose settings you want to change and press

F5

.

5. Select the

Auto logout (min)

entry and press

Enter

.

6. Enter a number between

1

and

99

minutes to set the auto logout and press

Enter

.

7. Press

F2

to save your settings.

Auto-disconnecting the access to a target module

The user module can be configured so that the active access to a target module is

auto-disconnected after the user has been inactive for a certain amount of time.

If the on-screen display is opened at the moment of disconnection, it remains on the

screen even after it has been auto-disconnected.

In case the on-screen display is closed at the moment of

disconnection, the message displayed on the right appears

on the screen of the user console.

off:

The connected USB input devices do not need to be reini-

tialised (recommended setting).

all:

All USB devices are regularly reinitialised.

only faulty:

The status of USB devices is monitored. If the communica-

tion with a USB devices is interrupted, the device is reini-

tialised.

ADVICE:

Use the menu’s search function or the sort criteria (see page 9 ff.) to limit

the selection of list entries.

NOTE:

The value »0« deactivates the automatic user logout.