Guntermann & Drunck DVICenter DP16 Configuration and Operation User Manual

Page 116

background image

System settings and functions

108 · G&D DVICenter

For each tested port, the following data is determined and displayed:

How to show cable information:

1. Press

Ctrl+Num

(default) to open the on-screen display.

2. Press

F12

to open the Information menu.

3. Select

Cable information

and press

Enter

.

4. Enter the number of the port you want to measure and press

Enter

.

Value

Meaning

Result

Ok:

The cable connection to the remote station was measured suc-

cessfully.

Error:

There is no or a faulty cable connection to the remote station.

Busy:

The measurement could not be finished within the given time

frame.

Pair:

Wire pairs displayed by columns (

1-2

,

3-6

,

4-5

and

7-8

)

Value

Meaning

State

Open:

The wire pair has an open end.

Possible causes are a cable break or a cable that was not connected.

Short:

The wire pair is short-circuited.

XShrt:

The wire pair is connected to another wire pair.

X1-2:

The wire pair is connected to wire pair 1-2.

X3-6:

The wire pair is connected to wire pair 3-6.

X4-5:

The wire pair is connected to wire pair 4-5.

X7-8:

The wire pair is connected to wire pair 7-8.

Imped:

The wire pair shows a faulty terminating resistor (impedance

error).

Length

Approximate length of the successfully measured distance to the

remote station

Dist.

Approximate distance (of the cable connection) to the point of failure

Skew

Time delay of the signals on the different wire pairs

IMPORTANT:

Any measured connections are interrupted during measuring!

NOTE:

The port to which „your“ user module is connected to cannot be meas-

ured.