Auto scanning all target modules (autoscan), Applying the autoscan function, Auto scanning all target modules (a – Guntermann & Drunck DVICenter DP16 Configuration and Operation User Manual
Page 40: Applying the

Switching the target modules automatically or manually
32 · G&D DVICenter
Switching the target modules automati-
cally or manually
Auto scanning all target modules (Autoscan)
The Autoscan function successively accesses all target modules that are mentioned in
the active scancode set and available to the user.
The Scantime setting (see page 33) enables you to define how long a target module is
to be accessed.
When accessing the target modules, the workplace name, the name of the currently
accessed target module, and a note regarding the Autoscan function are displayed.
Applying the Autoscan function
How to start the Autoscan function:
1. Press the
Ctrl+Num
(default) hotkey to open the on-screen display.
2. Press
F9
to call the Operation menu.
3. Press
A
or select the
A - Autoscan
entry and press
Enter
.
How to stop the Autoscan function:
1. Press the hotkey
Ctrl+Num
(default) to call the on-screen display.
This causes the Autoscan function to stop.
NOTE:
If the Autoscan function is active, the keyboard and mouse inputs are trans-
mitted to the currently accessed target module.
During your inputs, the Autoscan function stops and continues after you finished
your inputs.
Requirements for using the Autoscan function:
Creating a scanmode set (see page 36)
Assigning a scanmode set to a user account (see page 39)
ADVICE:
After the on-screen display has been called, you can activate the Autoscan
function in the Select menu by pressing
Ctrl+A
.