Copying the target module config settings – Guntermann & Drunck DVICenter DP16 Configuration and Operation User Manual
Page 72

Target modules
64 · G&D DVICenter
4. Select the target module you want to delete and press
F4
.
5. Use the arrow keys to select
Yes
and press
Enter
to respond to the prompt for
confirmation.
Copying the target module config settings
If a target module of the KVM matrix system is replaced by another device, it is pos-
sible to copy the previous config settings to the new device.
After the config settings have been copied to the new device, it can be operated
immediately.
How to copy the target module config settings:
1. Press the
Ctrl+Num
(default) hotkey to open the on-screen display.
2. Press
F11
to call the
Configuration
menu.
3. Select the
Target
entry and press
Enter
.
4. Select the active target module to which you want to copy the config settings of a
target module that is switched off or disconnected from the matrix system and
press
F7
.
5. Select the target module whose settings you want to copy and press
Enter
.
6. Use the arrow keys to select
Yes
and press
Enter
to respond to the prompt for
confirmation.
7. Press
F2
to save your settings.
ADVICE:
Use the menu’s search function, the view filter or the sort criteria (see
page 9 ff.) to limit the selection of list entries.
IMPORTANT:
The target module whose settings you want to copy is afterwards
deleted from the KVM matrix system.
ADVICE:
Use the menu’s search function, the view filter or the sort criteria (see
page 9 ff.) to limit the selection of list entries.
NOTE:
Only target modules that are switched off or disconnected from the sys-
tem are listed in this menu.