User modules

G&D DVICenter · 77

4. Select the

Keyboard support

entry and press

F8

to select one of the following

options:

5. Press

F2

to save your settings.

Copying the user module config settings

If a user module of the matrix system is replaced by another device, the config set-

tings of the device can be copied to the new device.

The new device can be operated immediately.

How to copy the user module config settings:
1. Press the

Ctrl+Num

(default) hotkey to open the on-screen display.

2. Press

F11

to call the Configuration menu.

3. Select the

Console

entry and press

Enter

.

4. Select the active user module to which you want to copy the config settings of an

inactive or disconnected user module. Press

F7

.

5. Select the user module whose settings you want to copy and press

Enter

.

6. Use the arrow keys to select

Yes

and press

Enter

to respond to the prompt for con-

firmation.

7. Press

F2

to save your settings.

Deleting a user module from the matrix system

If the matrix system is not able to detect a target module that already has been con-

nected to the system, the device is considered inactive.

Therefore, you have to manually delete the list entry of the user module you want to

permanently remove from the system.

yes:

User module can be started only when a keyboard is connected.

no:

User module can be started without a keyboard (default).

IMPORTANT:

The user module whose settings are to be copied is deleted from the

system.

ADVICE:

Use the menu’s search function or the sort criteria (see page 9 ff.) to limit

the selection of list entries.

NOTE:

This menu only list user modules that are switched off or disconnected

from the system.

NOTE:

Only inactive user modules can be deleted by the administrator and all

users with the Superuser right.