CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–16

Item

Description

TxPLL

(Alarm) The Tx Clock PLL is railed high or low indicating that the Tx Clock Source is

substantially different than the rate of the Tx data.

InpSigLoss

(Alarm) Input Signal Loss indicates that no traffic is being seen by the OC3/STM-1 interface

on the TX-IN connector.

RxPLL

(Alarm) The Rx Clock PLL is railed high or low indicating that the Rx Clock Source is

substantially different than the rate of incoming data.

RxOF

(Alarm) Rx Overflow indicates that the traffic received by the demod is exceeding the clock

RxClock setting and is therefore overflowing the buffer causing the buffer to re-center and
take a data hit.

RxUF

(Alarm) Rx Underflow indicates that the traffic received by the demod is not keeping up with

the clock RxClock setting and is therefore underflowing the buffer causing the buffer to re-

center and take a data hit.

 
Using TxPLL as the example:

Tx Pll Mask: Masked
Alarm Fault Mask Fault-Tx On

 
The  top  line  notes  the  active  mask  selection.  On  the  bottom  line,  use  the  W  X  arrow  keys  to 
select AlarmFaultMask, or Fault‐Tx On for the TxPll and InpSigLoss menus, or AlarmFault, or 
Mask for the RxPllRxOF and RxUF menus. Press ENTER when done. Note the following: 
 

Mask Type

Description

Redundancy Switchover and Tx Mute

Alarm

Alarms can be viewed from the Monitor: Live

Alarms menu (Sect.5.2.4.1). Alarms cause the
Unit Status LED to turn AMBER.

An alarm WILL NOT cause a redundancy

switch and WILL NOT mute the Tx carrier

Fault

Faults can be viewed in the Monitor: Stored-

Events log (Sect. 5.2.4.2).

Faults cause:

• The Unit Status LED to turn RED

• The J1 Alarm Connector to show a Fault

A fault WILL cause a redundancy switch

and WILL mute the Tx carrier

Mask

Masking the event has the effect of ignoring the

event – it can no longer be logged and is not
seen in any menu.

Mask WILL NOT cause a redundancy

switch and WILL NOT mute the Tx carrier

Fault-Tx On

Faults can be viewed in the Monitor: Stored-

Events log (Sect. 5.2.4.2).

Faults cause:

• The Unit Status LED to turn RED

• The J1 Alarm Connector to show a Fault

A Fault-Tx On WILL cause a redundancy

switch and WILL NOT mute the Tx carrier