Comtech EF Data CDM-750 User Manual

Page 76

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Updating Firmware

MN-CDM750

4–10

• Type "bye" to terminate the FTP session, and then close the Command‐line window. 

 
3. Verify that the PC‐to‐Unit FTP file transfer was successful. Use the Front Panel, the Remote 

Control Interface, or the CDM‐750 Web Server Interface ‘Status | Firmware’ page to review 
the loaded firmware (per the methods explained in Sect. 4.2Step 1D)

 

4. Use  the  CDM‐750  Front  Panel  or  the  Web  Server  Interface  to  select  the  firmware  boot 

image and reboot the unit: 

 

From  the  CDM‐750  Front  Panel  /  VFD    First,  use  the  keypad  ◄  ►  arrow  keys  to 

navigate to the SELECT: Utility Æ Firmware Æ Select screen. Then, use the keypad ▲▼ 
arrow keys to select the other image. Press ENTER when done. 

 

The CDM‐750 front panel will then display:  

 

Cycle power now
to boot from the selected image.

Use the rear panel ON/OFF switch to cycle the power as prompted. Be sure to note the 
firmware version that displays on the front panel ‘splash’ screen upon successful reboot: 

Comtech CDM-750 Advanced High-Speed

Trunking Modem ver x.x.x

Programming ModemApp to ModemCard Flash.

…PLEASE WAIT

 

Then:  

 

ModemCard Flash programming was successfully
completed.

 

On the user PC – Use the CDM‐750 Web Server Interface to select the Boot Image and 

reboot the modem. 
 
o Select the desired Boot Image slot from the Firmware Image Config section of the 

Configuration  |  Utilities’  page.  Use  the  Next  Reboot  Image:  drop‐down  list  to 
select Image1 or Image2.  

When  booting  into  a  new  image,  if  the  Top  Card  Application  has  been 
changed,  an  additional  step  will  occur  as  the  CDM‐750  downloads  to  a 
different  flash  memory.  This  additional  upload  takes  approximately  two 
minutes. 
 
During  the  reboot  cycle,  the  following  messages  appear  on  the  CDM‐750 
front panel display: