C.6 monitoring acm performance and statistics – Comtech EF Data CDM-750 User Manual

Page 254

background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Appendix C

MN-CDM750

C–18

C.6

Monitoring ACM Performance and Statistics

Chapter 3. REAR PANEL CONNECTORS 
Chapter 5. FRONT PANEL OPERATION 
Chapter 6. ETHERNET‐BASED REMOTE PRODUCT MANAGEMENT 
Chapter 7. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT 

 
The CDM‐750 provides a number of ways to monitor the ACM system: 
 

Via the CDM‐750 Front Panel: Use the MONITOR: ACM front panel menu to view the 

current Tx and Rx ModCod , as well as the Local and Remote Es/No. 
 
The Es/No displays values between –3.0 dB and +23.0 dB, with a resolution of 0.1 dB. If 
either the local or remote demodulator is unlocked, the Es/No will display ‘No Sync’.  
 
Note that you may often see that the RX ModCod is “00”. This is normal when there is 
no real data being received. DVB‐S2 states that when no data is available, the modulator 
should insert a Dummy PLFRAME. These Dummy PLFRAMEs are used to keep the demod 
locked, but contain no user data and have a ModCod value of “00”. 
 
If  you  wish  to  see  the  exact  detail  of  the  ModCod  (data  rate,  modulation,  code  rate), 
view  these  parameters  using  the  INFO:  TX  or  INFO:  RX  screens.  Furthermore,  if  using 
the  CONFIG:  TX  or  CONFIG:  RX  menus,  both  the  symbol  rate  and  data  rate  are 
displayed.  All  of  these  screens  update  dynamically  –  if  a  ModCod  changes,  the 
parameters are refreshed on these displays. 
 

Via the CDM‐750 Remote Control and Ethernet Management Interfaces: As described 

for  the  CDM‐750  Front  Panel,  this  information  is  available  via  remote  queries  issued 
over the Remote Control Interface (Serial or Telnet), and by using the Ethernet Remote 
Product Management Interfaces – SNMP, or the CDM‐750 Web Server interface via the 
Status | Status and Status | ACM pages.  
 

Via Oscilloscope: If you have access to an Oscilloscope in X‐Y mode, Pins #3 and #11 on 

the CDM‐750 rear panel  J1 | ALARMS connector provide analog voltages to monitor the 
constellation.  The  advantage  here  is  that  ModCod  changes  may  be  viewed 
instantaneously. 

 

Via Internal BERT Tester: When using the Ethernet IP interface, it is not an easy matter 

to verify BER performance. A way to verify that the ACM link is meeting performance is 
by  using  the  internal  BERT  tester.  Not  only  will  the  internal  BERT  verify  BER 
performance, it is also tolerant of the change in bit rate that accompanies a change in 
ModCod. The BERT can be used to confirm that there are no sync losses or bursts of bit 
errors when a ModCod changes.